10, 20, 30 L PHARMA JACKETED GLASS REACTORS


Complete jacketed glass reactors for pharmaceutical use on our unique free standing movable frame.
Industrial design, high performing industrial stirring system and connections.

Main features:
- Gmp compliant;
- Total safety: no residues or stagnant liquids;
- For pharmaceutical use, FDA compliant (PTFE and borosilicate glass in contact with products);
- Multi-purpose;
- Complete glass piping;
- Compact design;
- It can be placed under walk-in hoods (up to 20L version)
- Atex certification available on request.

WORKING CONDITIONS:
Design Temperature : -50 °C / 180 °C
T D : 80 °C
Design Pressure : -1mbar / 0,49 bar
Max vacuum: 5mbar

REACTION GROUP
-DN300 Jacketed vessel;
-10L, 20L and 30L nominal capacity;
-DN300 Glass lid 7 necks:
a) DN25 Central for stirring;
b) DN80 with closure for solid loading;
c) DN25 for liquid inlet;
d) DN50 for vapour line;
e) DN40 closed and free (on request);
f) DN40 closed and free (on request);
g) DN40 closed and free (on request);
-AISI304 Stirring shaft, PTFE-coated;
-PTFE Stirring anchor blade;
-PTFE/glass mechanical seal - ATSA25/16;
-25mm discharge bottom valve, Gmp compliant.

POWER SUPPLY:
ELECTRICAL MOTOR 140Watt, approx. 230V or
COMPRESSED AIR MOTOR air worn out 260 l/min at 6bar

ULTRA GMP VALVE
-Total safety;
-Gmp/Pharma compliant;
-The valve completely drains leaving any stagnating liquid;
-Compact design;
-Constant valve closure pressure during temperature changes;
-Compensation of thermal expansion;
-Design helps preventing shutter head over-tightening.


Pt100 TEMPERATURE PROBE
-Product temperature can also be controlled with very low liquid levels;
-The probe is placed inside drain valve freeing up a nozzle;
-Quicker temperature reading when compared to sensor placed on lid;
-No risk of glass sensor breakages due to accidental impacts with solid suspensions;
-Pneumatic valve on request.


DIMENSIONS:
Reactor dimensions: mm800x660x1890H
Box dimensions (fumigated wooden box) mm950x800x2200H

WEIGHT: APPROX 130 Kg

CERTIFICATIONS:
-Gmp certification for bottom valve;
-Machinery Directive
-User Manual


NOTE
The equipment can work in dangerous areas or with inflammable solutions only in ATEX version (available in request)

(r.270320)





  Steroglass
 
Code
Supplier
 
Code
                                              
                                              
                                              
Richiedi un preventivo SQHK078027 KC27203 10L PHARMA GLASS REACTOR w/o electric motor   
Sempre disponibile a magazzino SQHK077663 N.D. 20L Compact Pharma Reactor w/o electric motor 
Richiedi un preventivo SQHK078026 N.D. 30L Compact Pharma Reactor w/o electric motor 
Richiedi un preventivo SQUAO080339 N.D. Electric motor model St1800 DF                
Richiedi un preventivo SQHK083381 KC35378 10L PHARMA GLASS REACTOR w/o pneumatic motor  
Richiedi un preventivo SQHK083382 KC35379 20L PHARMA GLASS REACTOR w/o pneumatic motor  
Richiedi un preventivo SQHK083383 KC35380 30L PHARMA GLASS REACTOR w/o pneumatic motor  
Richiedi un preventivo VAJQ080147 GM2AMARV92NLP PNEUMATIC AIR MOTOR                           



Brand: STEROGLASS In the same brand :
Related items:

    For this product there are no related articles