HYPERLAB PLUS and basic wine analyzers
Contact our expert for more informations.
Hyperlab wine analyzer represents the most advanced solution for analytical control automation in the oenological field.
The results of the analyses are extremely accurate and permit the user to work in an extremely time-efficient manner thus allowing for both quality analysis improvement and cost-benefit optimization.
Hyperlab is an automatic multi-parametric analyzer with Flexible Random Access, i.e. it can fully perform all the manual operating procedures automatically.
Benefits
-
BEST QUALITY AND ECONOMICAL
Hyperlab automation guarantees the greatest data results accuracy and precision, thus significantly reducing analysis costs by about seven times when compared with manual methodologies.
With Hyperlab reagents are reduced to minimum: a single determination requires less than 300 microlitres. -
METHODS IN MEMORY
Acetic acid, Citric acid, D-Gluconic acid, D-Lactic acid, L-Lactic acid, L-Malic acid, Pyruvic acid, Tartaric acid, Acetaldehyde, Anthocyanin, Alpha Amino nitrogen, Ammoniacal nitrogen, Calcium, Catechins, Chlorides, Iron, Glycerol, Glucose/Fructose, Glucose/Fructose (for high sugar concentration analysis on musts), Magnesium, Total polyphenols, Potassium, Copper, Free and Total SO2, Optical reference solution.
Other methods:
IC (colour intensity 420+520), shade (420/520), ICM (modified colour intensity 420+520+620), GRB (% yellow, red and blue colour on total colour. This is an indispensable determination for products undergoing refining or micro-oxygenation process).
The optical reference solution gives the technical specifications of the instrument regardless its kit performances.
The best way to demonstrate Hyperlab precision is the use of bicromatic optical solution (suggested by IUPAC - International Union of Pure and Applied Chemistry).
-
Calibrations
Reagent blank subtraction, 1 to 8 calibrators for single test. Linear and non-linear regressions with three types of data extrapolation: cubic, polynomial and log-logit.
-
Innovative software and hardware
Innovative software: Windows system, user-friendly functions, touch screen technology, switch-on/off with programmable start-up, on-line support.
Monitor: Information on programmed methods, selected analyses, n° of analyses to be run, calibration and check status.
Reagent panel: Displays the samples position and their volumes.
Samples: Samples status display. Possibility of adding, removing or modifying samples during the analysis.
Working lists: Unlimited working lists can be used simultaneously. Tests may be added or removed and automatically repeated if wrong. Inspection of kinetics reaction can be performed for single tests.
-
Data processing and Tests
Data processing
Results can be re-calculated at the end of the analysis by correlating them to one or more samples with fixed value. The new regression line will show the value obtained by the re-calculation.
TestsAll the analyses regarding a spectrophotometric determination can be automatized.
Technical features
TECHNICAL SPECIFICATIONS HYPERLAB PLUS and BASIC
VOLUMES (Hyperlab Plus and Basic)
- Sample: 2-300µl, precision 1% at 10µl
- Reagent: 5-350 µl, precision < 1% at 250µl
- Reaction (sample + reagent): 220-350µl
- Mixing in cuvette after dispensation
DILUTION (Hyperlab Plus and Basic)
Automatic programmable dilution for each sample
- Factors: 1:1 1:4 1:10 1:40 1:100
ANALYTICAL SPEED
- 125...200 analyses/hour - Hyperlab Plus
- 100...180 analyses/hour - Hyperlab Basic
TEMPERATURE CONTROL (Hyperlab Plus and Basic)
- Refrigerated reagent at 15°C below ambient temperature
- Reading cuvette with programmable heating
- Reagent preheating in sucking needle
TYPES OF TESTS (Hyperlab Plus and Basic)
- Endpoint, Bichromatic endpoint, Differential endpoint, Differential endpoint sample blank, Derivatives, Fixed time, Kinetic.
SAMPLES TRAY
- 60 samples positions - Hyperlab Plus
- 30 vials and 20 cups - Hyperlab Basic
REAGENTS TRAY
- 30 positions refrigerated tray - Hyperlab Plus
- 26 positions refrigerated tray - Hyperlab Basic
SAMPLING NEEDLE
- Glass ceramics stroke needle, capacitance sensor, reagent pre-heating - Hyperlab Plus
- Stainless steel needle, capacitance sensor, optional reagent pre-heating - Hyperlab Basic
REACTION CUVETTE ROTOR (Hyperlab Plus and Basic)
- 80 BIONEX® cuvettes replaceable singularly, over 20.000 tests
WASHING STATION
- 6 dispensing needles for washing solution, 6 sucking needles, 1 drying needle, 8 washing cycles for each cuvette - Hyperlab Plus
- 4 dispensing needles for washing solution, 5 sucking needles, 1 drying needle, 6 washing cycles for each cuvette - Hyperlab Basic
OPTICAL GROUP (Hyperlab Plus and Basic)
- 1 halogen lamp (6V, 10W) with extended UV emission, 2 focusing lenses, 10-position interference filters, 8 positions provided with interference filters of 340, 420, 520, 546, 578, 620, 650, 700 mm, 1 free position and 1 for dark reading.
DATA RE-PROCESSING (Hyperlab Plus and Basic)
- Results can be re-calculated at the end of the analysis by correlating them to one or more samples with fixed value
INNOVATIVE SOFTWARE (Hyperlab Plus and Basic)
Extremely user-friendly. Optimized random system allows the user to work efficiently and comfortably. Operating system: Windows
- 2x20lt plastic tanks for washing and discharge water- Hyperlab Plus
- 2x5lt plastic tanks for washing and discharge water- Hyperlab Basic
SAFETY SHIELD SENSOR
- Available - Hyperlab Plus
- Not available: Hyperlab Basic
DIMENSIONS (Hyperlab Plus and Basic)
- LxDxH 60x66x50 cm
WEIGHT
- 38Kg Hyperlab Plus
- 32Kg Hyperlab Basic
WORKING CONDITIONS (Hyperlab Plus and Basic)
- 16-30°C max relative moisture 80%
POWER SUPPLY (Hyperlab Plus and Basic)
240/100Vac, 50/60 Hz single phase with ground
POWER ABSORPTION (Hyperlab Plus and Basic)
Less than 200 VA (external Pc excluded)
The sampling arm, controlled by a microprocessor, carries out the sample taking, its dilution (if required by the method) and the reagents suction. Both the sample and the reagents are dispensed in the reaction cuvette and remain there long enough, under constant and controlled temperature, to allow for a reaction to fully take place.
The reaction product is given by means of a preset wavelenght and the absorbance obtained is expressed in a concentration value with appropriate algorithms. During the process the washing phases take place between the aspiration and dispensation cycles, thus avoiding any contamination risks between the reagents and samples. After the cuvette is dried, it undergoes an accurate optical control before a new analysis is run.
Industries
Applications
Product codes
Steroglass code | Brand code | Description |
---|---|---|
SQRQ060129 | HYPERLAB | Hyperlab plus wine analyzer |
SQRQ065038 | BASIC | Hyperlab basic wine analyzer |
CDDS060963 | 19 inch flat monitor | |
SQRQ074351 | Hyperlab basic no refrigerated station |